System: 18XS72 Indoor/Outdoor: XS1872/C1872
Grille: PNR-XS1872
Ceiling Recessed Air Conditioner
Power V/PH/Hz 230/208/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor DC Rotary Inverter
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
Weight Indoor Outdoor
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
(A) 20
(A) 20
General Data (at 230V)
1
(A) 9.8/10.6-20
Propeller
16-17/32-1
Direct-3
(RPM) 8-820/850
(W) 40-1
16
(Pints/H) 4.89
(BTU/H) 17,500 (4,000-17,500)
(BTU/H) 10,600
(BTU/H) 6,900
(uncrated) 11-1/16 x 22-5/8 x 22-5/8
(W) 1860(250-1860)
Aluminum Fin and Copper Pipe
Corrugated Plate - Inner Rifl ed
(in.) 9/32”
2.87
Split System Submittal Data
Electric Expansion Valve
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
2-18.1
(sq.ft.)) 6.4
(lbs.) 35.3 97.0
(A) 8.3(1.2-8.3)
(in O.D. Dishcharge) 1/4”
(in O.D. Suction) 1/2”
(HIGH)) 524
(A) 0.5
R410A
(in.) H x W x D
(crated) 11-13/32 x 24-3/16 x 28-1/8
(cu.ft.) 4.59 9.88
(lbs.) 41.9 105.8
(dB-A) 51
Turbo
12-5/8/5-3/4-1
3+Auto
(RPM, High)) 8-720
(W) 30-1
Aluminum Plate Fin & Copper Tube
Slit Plate & Inner Rifl ed
(in.) 9/32”
2-18.1
(sq.ft.)) 2.94
(Hi/Med/Low) 341/294/253
(A) .3
(in.) 23/32”
(Hi) (dB-A) 44
Flare
100
50
(uncrated) 26-3/8 x 34-21/32 x 11-7/32
(crated) 29-1/8 x 39-27/32 x 14-31/32
Print Form
Page view 0
1 2

Summary of Contents

Page 1 - Split System Submittal Data

System: 18XS72 Indoor/Outdoor: XS1872/C1872 Grille: PNR-XS1872Ceiling Recessed Air ConditionerPower V/PH/Hz 230/208/1/60Circuit Am

Page 2 - Dimensions

DimensionsFeaturesControlsRemote ControllerTemperature ControlTimerNight SetbackAir LouverPower Failure Automatic RestartSelf-DiagnosisAir FilterAir C

Comments to this Manuals

No comments