INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D'INSTRUCTIONS SF-L6111 FREEZER CONGELADOR CONGELATEUR SANYO Scientific SANYO E & E America
FREEZER COMPONENTS Control panel 9 o DOOR Q ~ 1 8 o ALARM 2 3 4 7 -, ,-, ~ -, I - -TEMPERATURE(-C) 8CD 5 6 1. Alarm test key (ALARM TEST): Buzzer wi
INSTALLATION Installation site To operate this unit properly and to obtain maximum performance, install the unit in a location with the
INSTALLATION Installation 1. Remove the packaging materials and tapes Remove all transportation packaging materials and tapes. Open the doors and ve
OPERATING INSTRUCTIONS Temperature setting Table 1 shows the basic operation method. Perform key operation in the sequence indicated in the table
OPERATING INSTRUCTIONS Offset The difference between chamber and indicated temperature can be arranged by key operation. As an example, Table 2 shows
OPERATING INSTRUCTIONS Key lock operation This unit incorporates a key lock feature that can inhibit tampering using the keys on the control panel. T
ALARMS AND SAFETY FUNCTIONS This unit has the alarm and safety functions shown in Table 4, and also a self-diagnostic function. T bl 4 AI a e arms a
While you are defrosting . . . . Freezer is desigried to send a buzzer message (but not remote alarm) for every 30 minutes to remind that the defrosti
MAINTENANCE &WARNING Always disconnect the power supply to the unit prior to any repair or maintenance of the unit in order to prevent electric sh
TROUBLESHOOTING If the unit malfunctions, check the following potential causes before calling for service. In the case of inadequate refr
Note: 1. No part of this manual may be reproduced in any form without the express written permission of sANYO. 2. The contents of this manual ar
SPECIFICATIONS Name Laboratory Freezer Model SF-L6111 External dimensions 345/8" H x 235/8" W x 25 31/32" D (880 H x 600 W x 652 D (mm
6 CAUTION Please fill in this form before servicing. Provide this form to the service engineer to keep for safety. 1. Freezer contents: Risk of infec
PRECAUTIONS FOR SAFE OPERATION It is imperative that the user complies with this manual as it contains important safety advice. Items and pr
PRECAUTIONS FOR SAFE OPERATION [ _____ Lt_!W_A_R_N_1 N_G ________ ] '" Do not use the unit outdoors. Current leakage or electric shock may
PRECAUTIONS FOR SAFE OPERATION l ___ &_!W_A_R_N_IN_G ____ J ~ Always disconnect the power supply to the unit prior to any repair or maintenance of
PRECAUTIONS FOR SAFE OPERATION [ _____ 6_! _CA_U_T_IO_N_J '" Do not climb onto the unit or do not put articles on the unit. This may cause
CAUTIONS FOR USAGE 1. If the unit is unplugged or the power to the unit is interrupted, do not restart the unit for at least 5 minutes. This protec
ENVIRONMENTAL CONDITIONS This equipment is designed to be safe at least under the following conditions: 1. I ndoor use; 2. Altitude up to 2000 m; 3. A
FREEZER COMPONENTS 8. Shelves 10. Temperature sensor (behind the fan cover) 9. Magnetic door gasket .--6. Remote alarm terminal (behind the kick plate
Comments to this Manuals