Sanyo KHS1822 User Manual

Browse online or download User Manual for Car speakers Sanyo KHS1822. Sanyo KHS1822 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
HIGH
EFFICIENCY
SERVICE MANUAL (Basic Information)
KHS1822 / CH1822
SPLIT SYSTEM AIR CONDITIONER
8526481021800 REFERENCE NO. WM700796
W
Indoor Unit Outdoor Unit
CH1822
KHS1822
92-267 S/M (Basic) 00.12.13 10:42 AM ページ A
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - SPLIT SYSTEM AIR CONDITIONER

HIGHEFFICIENCYSERVICE MANUAL (Basic Information)KHS1822 / CH1822SPLIT SYSTEM AIR CONDITIONER8526481021800 REFERENCE NO. WM–700796WIndoor Unit Outdoor

Page 2

5WM– 700796208VKHS1822 / CH1822TC: Total Cooling Capacity (BTU/H)SHC: Sensible Heat Capacity (BTU/H)kW: Compressor Input (kW)Remarks: Rating condition

Page 3 - SERVICE MANUAL

6WM– 7007965. HEATING CAPACITY1 Phase 60Hz 230VIndoor Entering Air Temperature 70°FTemperature of Air Entering Outdoor Coil(°F DB at 75% RH)Heating

Page 4 - Please Read Before Starting

7WM– 7007961 Phase 60Hz 208VIndoor Entering Air Temperature 70°FTemperature of Air Entering Outdoor Coil(°F DB at 75% RH)Heating Capacity (BTU/h)30,

Page 5 - Table of Contents

Heat exchangerWide tubeAccumulatorCompressorWide tubeservicevalveDrierCheckvalve StrainerCapillaryMuffler4-wayvalveNarrow tubeservicevalveO.D.5/8"

Page 6 - 1. OPERATING RANGE

9WM– 7007967. ELECTRICAL DATA● Electrical CharacteristicsKHS1822 / CH1822Remarks: Rating conditions are:Cooling: Outside air temperature 95°F DB/75°

Page 7 - 2. SPECIFICATIONS

10WM– 700796● Electric Wiring DiagramIndoor Unit: KHS1822Terminal plate1234FROM OUTDOOR UNIT33113322111122BLKBLKBLKBLK1122SG-OUT 3PSUP2P 2P2PSECTH2T

Page 8 - 3. DIMENSIONAL DATA

11WM– 700796Outdoor Unit: CH18221 1221 1221 13311221122112211 1221 1221 1221 1222PPRY2PSECTH1TH2TH3LOPRSREDBLKBLKBLKBLKBLKBLKThermistor (coil)Thermis

Page 9 - 4. COOLING CAPACITY

For parts or service contactSFS Corporation: 1200 West Artesia Blvd., Compton, California 90220Printed in U.S.A.CORPORATION1991/Nov./12MSANYO Canada I

Page 10 - KHS1822 / CH1822

92-267 S/M (Basic) 00.12.13 10:42 AM ページ i

Page 11 - Heat-pump with back-up heater

iiWM– 700796SERVICE MANUALKHS1822 / CH1822(Basic Information)92-267 S/M (Basic) 00.12.13 10:42 AM ページ ii

Page 12

iiiWM– 700796IMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operatingstandards. As the installer or servic

Page 13 - 6. REFRIGERANT FLOW DIAGRAM

Table of ContentsPage1. OPERATING RANGE...

Page 14 - 7. ELECTRICAL DATA

1WM– 7007961. OPERATING RANGETemperature Indoor Air Intake Temp. Outdoor Air Intake Temp.CoolingMaximum 95°F DB / 71°F WB 115°F DBMinimum 67°F DB / 57

Page 15 - WARNING:

2WM– 700796Model No.Indoor unit KHS1822Outdoor unit CH1822Cooling HeatingCapacityBTU/h 16,500 / 16,000 18,000 / 17,600kW 4.84 / 4.69 5.27 / 5.16Air ci

Page 16 - Outdoor Unit: CH1822

WM– 70079633. DIMENSIONAL DATAIndoor Unit: KHS1822Outdoor Unit: CH182238-31/3214-3/167-25/32 Rear panel(Center point of gravity)Drain hose O.D. 1-1/

Page 17 - H408/12M Printed in U.S.A

4. COOLING CAPACITY230VKHS1822 / CH18224WM– 700796TC: Total Cooling Capacity (BTU/H)SHC: Sensible Heat Capacity (BTU/H)kW: Compressor Input (kW)Remark

Comments to this Manuals

No comments