Sanyo VSP-9000 User Manual Page 90

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 89
English
89 Others
Appendix
(Continued)
b
bb
b Special Code Chart
These functions can be loaded by entering their special codes.
ERNITEC SATURN............................................ 89
MARK MERCER ................................................ 90
PELCO .............................................................. 92
SENSORMATIC................................................. 94
b
bb
b
ERNITEC SATURN
Code Function
AUTOPAN
301 Saves the current position of the first limit switch.
302 Saves the current position of the second limit switch.
XXX XXX= 0 255: Auto-pan speed (0=min, 255=max)
Note: Cannot use with Saturn type.
PATROL
1000 Deletes patrol order.
1XXX XXX= 1 128: Writes preset position XXX into patrol order.
2000
2XXX
Makes patrol order valid.
X= 001 128: Deletes preset position XXX from patrol order.
3XXX X= 000 255: Waiting time (in seconds) upon reaching specified position
Example:
1000 Deletes previously defined order.
1001 Writes preset position 1 into order.
1005 Writes preset position 5 into order.
1006 Writes preset position 6 into order.
2005 Deletes preset position 5.
OTHER FUNCTIONS
4XXY Dome cameras can be set to automatically move to the "return position" after a
set stopping time passes.
XX= 01 99: Return position (Cannot select positions No. 100 to No. 128)
Y= 0 9: Return time
0: 10 seconds, 1: 20 seconds, 2: 30 seconds, 3: 40 seconds, 4: 1 minute,
5: 2 minutes, 6: 5 minutes, 7: 10 minutes, 8: 20 minutes, 9: 40 minutes
4000 Invalidates movement to return position.
Example:
4216: After stopping for 5 minutes (Y=6), move to position 21 (XX=21).
400 Text display/non-display (switch)
500 Backlight compensation ON/OFF (switch)
9999 Initializes the dome camera internal memory.
Page view 89
1 2 ... 85 86 87 88 89 90 91 92 93 94 95 96

Comments to this Manuals

No comments