Sanyo PLC-WXL46 User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
PLC
-
WXE46/WXL46
Basic Serial Command Specifications
11/24
6.5. POWER ON Command
Com
mand
C00” [CR]
Detail
When already Power is ON, nothing is done.
When sending this command during processing Countdown, Countdown is
terminated.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.6. POWER OFF Command Quick Power OFF
C01” [CR]
Detail
Power OFF (Standby)
When Power is OFF with ON/STAND-BY button of the remote control, Power
OFF?” is displayed. However, as soon as this command is sent, Quick Power OFF
is executed.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.7. POWER OFF Command
C02” [CR]
Detail
Power OFF (Standby).
The command operates the same Power OFF function as ON/STAND-BY button
of the remote control.
Once this command is sent, “Power OFF?is displayed. If this command is sent
again while it is displayed, Power OFF is executed.
When sending this command during Countdown, Countdown is terminated.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.8. Computer 1 Command
C05” [CR]
Detail
Select Computer 1 Input
Although Input search is set to On1/On2, the search is not executed with this
command.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.9. Computer 2 Command
C06
[CR]
Detail
Select Computer2 Input
Note 1) Although Input search is set to On1/On2, the search is not executed with
this command.
Note 2) When Monitor out is selected in a menu “Terminal”, the command is not
executed while projector returns OK”
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
Page view 10