OUTPUT TERMINALS
TAPE END OUT Terminal
During recording, when the end of the tape is
reached or when the tape counter reading indicates 2
hours 57 minutes or more, the output becomes 0V
(Low).
During autorepeat recording, when the end of the
tape is reached, the output become 0V (Low) for
about 2 seconds only.
To reset the output, press the STOP or EJECT
button.
TAPE END OUT Terminal Output Setting
1 Press the AUDIO ON/MENU button until the (SET
UP 3) menu is displayed.
2 Press the ] button, until the “TAPE END OUT”
setting is flashing.
3 Press the l (or j) button, to select the desired
output mode.
–3M. . . . . . . . . . . . The output become 0 V
(Low) when the tape counter
reaches “2:57:00” and/or
when the tape reaches the
end.
END . . . . . . . . . . . The output become 0 V
(Low) when the tape
reaches the end.
4 Press the PAUSE/SCAN button, the normal screen
is displayed.
WARNING OUT Terminal
If the tape stops or other problem, the output
becomes 0V (Low).
To reset the output, unplug the power cord then plug
it back in or press the ALL RESET button.
NOTE:
If the output is 0V (Low) due to the clog detect
function, it can be reset by simply pressing the STOP
button.
COM Terminal
Common GND (ground) terminal when connecting
other terminals to external devices.
Tape end or
2
H
57
M
00
S
5V (H)
0V (L)
(Output impedance: 5.7 k)
Output reset
<SET UP 3>
ALARM MODE Y1
ALARM SPEED 3H
ALARM DURATION 20S
TAPE IN MODE STOP
TAPE END MODE REW
TAPE END OUT -3M
CLOG DETECT. Y
Tape movement stop
5V (H)
0V (L)
(Output impedance: 5.7 k)
Output reset
GB