Chapter 5 Network Capture
Error messages Cause and corresponding
Set up the parameter.
Error when executing the communication. The parameter setting
(host name, capture port) has not been set.
Check parameter setting (+p.71)
It has not been registered to PJ
as a group.
Error when executing Start Communication or Start real time cap-
ture. The IP address of the computer has not been registered.
Register the IP address by using the web browser (+p.78)
Cannot be displayed as PJ is
under display.
Error when executing Start Communication or Start real time cap-
ture. The other capture, viewer or advanced card imager function
is now operating.
Wait until the communication function is available.
Cannot connect to PJ.
Cannot establish the connection with the network unit when
executing the Start communication, End communication, Capture
transfer, Start real time capture or End real time capture.
Check connection of the network cable.
Cannot transfer data to PJ.
Cannot transfer the data to the network unit when executing the
Start Communication, End Communication, Capture transfer, Start
real time capture or End real time capture. The time out period is
10 seconds.
Check connection of the network cable.
Cannot receive data from PJ.
Cannot receive the data from the network unit when executing
the Start Communication, End Communication, Capture transfer,
Start real time capture or End real time capture. The time out
period is 10 seconds.
Check connection of the network cable.
Other PC has authority.
Cannot complete "Network
Communication".
When executing the End communication, you cannot quit the
communication because other computer has an authority
Other PC has authority. Cannot
obtain authority.
Other computer has an authority.
The server name or address
could not be resolved.
When setting the parameter, the computer cannot find the set-
ting host name or IP address in the network.
Use available host name or IP address.
Invalid port number
When setting the parameter, the reserved port number is speci-
fied.
Check parameter setting (+p.71)
PJ has not started Network
Communication. Close the window
and open it again.
The projector might have turned off during the communication.
Check projector power and restart executing "Start communica-
tion".