20
Model STB0823H1
COOLING
Outdoor Unit Complete Unit
Fan Motor Compressor
Performance at 230 / 208V 1-phase 60Hz
Rating Conditions Running Amps. A 0.61 / 0.64 3.59 / 3.86 4.2 / 4.5
Power Input kW 0.142 / 0.132 0.798 / 0.788 0.94 / 0.92
Full Load Conditions Running Amps. A 0.61 / 0.64 4.29 / 4.46 4.9 / 5.1
Power Input kW 0.142 / 0.132 0.948 / 0.918 1.09 / 1.05
Rating Conditions : Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 90°F (32.2°C) D.B. / 73°F (22.8°C) W.B.
Outdoor Air Temperature 110°F (43.3°C) D.B.
HEATING
Outdoor Unit Complete Unit
Fan Motor Compressor
Performance at 230 / 208V 1-phase 60Hz
Rating Conditions Running Amps. A 0.61 / 0.64 3.39 / 3.66 4.0 / 4.3
Power Input kW 0.142 / 0.132 0.738 / 0.738 0.88 / 0.87
Full Load Conditions Running Amps. A 0.61 / 0.64 4.09 / 4.51 4.7 / 5.2
Power Input kW 0.142 / 0.132 0.898 / 0.888 1.04 / 1.02
Rating Conditions : Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.
Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.