7-3. Some part of air conditioner does not operate.
7-3-1. Only fan does not run.
7-3-2. Electric heater does not work.
Both for (cooling & electric heating models) and (heat pump model)
Measure resistance of electric
heater winding.
Blown
Check continuity for thermal
fuses.
Replace them.
Measure coil resistance of
heater relay.
Check PCB Ass'y. (Power pack)
(Only for heat pump model)
Check to see if the circuit of
heater thermostat is opened or
closed ?
Fan cannot
be turned.
OK
Check fan rotation.
Turn fan gently once or twice by
hand.
Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
Remove foreign
matter or repair.
Repair or replace.
Measure resistance of fan motor
winding.
Check fan motor capacitor and
4P-connectors (Socket and Plug).
Check PCB Ass'y . (Power pack)
(Only for heat pump model)