12. SERVICE PROCEDURES
7) Outdoor Fan Speed is not Switched from High to Low even when the Outdoor
Temperature Falls below 78
°F. (C2462R Type)
6) Outdoor Fan does not Run.
• Check resistance of fan
motor winding.
• Check fan motor capacitor
OK
• Check continuity between
terminals on the compressor
motor magnetic contactor.
• Check fan rotation.
Rotate the fan gently once
or twice by hand.
0633_X_S
• Check fan casing
for foreign matter
on the inside.
Remove foreign
matter or repair.
Repair or replace.
Fan cannot
be rotated.
Fan motor burnout
or foreign matter
in bearing.
8) Outdoor Fan Speed is not Switched from High to Med even when the Outdoor
Temperature Falls below 77
°F.
Outdoor Fan Speed is not Switched from Med to Low even when the Outdoor
Temperature Falls below 59
°F. (CL2462R Type)
1037_X_S
• Check the thermostat (23S).
• Check resistance of outdoor
temp sensor.
0722 _X_S
• Check outdoor unit P.C.B.
Ass’y