Sanyo C2462R User Manual Page 53

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 52
– 53 –
SM830092
Fan motor
capacitor
Compressor motor
capacitor
1041_X_S
Multimeter
Fig. 21
3) Checking the Electrical Parts
1
Power transformer ...........................Indoor unit *Measure the coil resistance.
Primary 230-208 V ; Measure the resistance between two WHT lead wire terminals
of socket connected to power transformer.
Secondary 19 V ; Measure the resistance between two BRN lead wires.
2
Power transformer (TR) ................. Outdoor unit *Measure the coil resistance.
Primary 230-208 V ; Measure the resistance between two WHT lead wire terminals
of socket jointed to power transformer.
Secondary 19 V ; Measure the resistance between two BRN lead wires.
3
Indoor fan motor (FMI) ............... Indoor unit *Measure the coil resistance.
Measure the resistance between each terminal of the socket connected to the
indoor fan motor.
4
Outdoor fan motor (FMO) ........... Outdoor unit *Measure the coil resistance.
Measure the resistance in the same manner as explained above 2 .
5
Motor capacitor ............ Both in indoor and outdoor unit
Remove the lead wires from the
capacitor terminals, and then place a
probe on the capacitor terminals as
shown in Fig. 21. Observe the deflec-
tion of the pointer, setting the resis-
tance measuring range of the multim-
eter to the maximum value.
The capacitor is “good” if the pointer
bounces to a great extent and then
gradually returns to its original posi-
tion.
The range of deflection and the deflection
time differ according to the capacity of the
capacitor.
NOTE
12. SERVICE PROCEDURES