Fixed IP configuration
This tutorial explains how to manually configure an HMP to connect to a specific network with a fixed IP address. Note that this
procedure assumes that you can access Control Center on the HMP already.
1) Collect information on your network configuration.
The following information should be available about your network:
A range of free IP addresses that can be allocated to the HMP unit(s) without network conflicts.
The correct subnet mask.
The address of the Gateway and the DNS servers if you want your HMP to be able to connect to the Internet.
2) Open the web interface of your HMP.
3) Select the Network Settings page.
Under the Connections tab note the current network configuration of the HMP, including the IP address, host name and MAC
address. If the player is configured to use DHCP, then these details will not be shown (see the Status page)
4) Enter the static IP address and the subnet mask.
Select the Static radio button.
Configured the HMP to use a static IP address in the range of the free IP addresses of your network.
Ensure that the subnet mask corresponds to your network configuration.
Other network settings are optional.
5) Validate the changes.
Validate the new network configuration with the Apply button.
Troubleshooting
Once the device has rebooted, you can check the new configuration by accessing Control Center as before, but using the new IP
address.
If your HMP has mistakenly been configured with the wrong IP address and can no longer be
contacted, the player must be reset to factory defaults.