Basic Serial Command Specifications
19/24
6.53. Computer 1 SCART Command
C
51
”[CR]
Detail
Select Scart input in Computer
1
.
Although Input search is set to On1/On2, search is not executed with this
command
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.54. Computer 1 Component Command
C
54
”[CR]
Detail
Select
Component
t input in Computer
1
.
Although Input search is set to On1/On2, search is not executed with this
command
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.55. AUTO PC ADJ. Command
C89” [CR]
Detail
Execute Auto PC Adj. function.
This command works the same way as “AUTO PC ADJ.” button of the remote
control.
Sending the command during Auto PC Adj. operation stops the operation. This is
the same operation as AUTO PC” button of the remote control.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.56. PRESENTATION TIMER Command
C8A[CR]
Detail
Execute Presentation Timer.
This command works the same way as “P-TIMER” button of the remote control.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.57. KEYSTONE Command
C8E” [CR]
Detail
Correct keystone distortion by reducing upper part of image.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
6.58. KEYSTONE Command
C8F” [CR]
Detail
Correct keystone distortion by reducing down part of image.
Response
Acceptable
[ACK] [CR]
Unacceptable
”[CR]
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24