SM830078
2. SPECIFICATIONS
(2) Major Component Specifications
(B) Outdoor Unit
MODEL No. CL4232
Source 230 - 208 V / 1 phase / 60 Hz
Controller P.C.B. Ass'y CR - CL2432 (Microprocessor)
Control circuit fuse 250 V, 3 A
Compressor Scroll (Hermetic)
Model ZR47KC - PFV
Source 230 - 208 V / 1 phase / 60 Hz
Nominal output W 2,200
Compressor oil cc 1,240
Coil resistance (Ambient temperature 77 °F) R – W : 0.475 , S – W : 1.850
Safety device Internal type
Overload relay models
Operating temperature Open °F 320 ± 9
Close °F 189 ± 20
Operating ampere (at 77 °F) A
Run capacitor VAC, µF 400 V, 50 µF
Crank case heater V, W 230 V, 30 W
Refrigerant amount charged at shipment lbs. (kg) R22 : 9.7 (4.4)
High pressure switch ACB
-
1UB11
Set pressure OFF kg/cm
2
30
ON kg/cm
2
24 ± 2.0
Fan Propeller
Number...diameter in. (mm) 1 ... 18 - 3/32 (460)
Fan speeds 3 (AUTO)
Fan motor
Model KFC6T - 91D6P × 2
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole ..... rpm (230 V, High) 6 ... 879
Nominal output W 110 × 2
Coil resistance BRN WHT : 67.14 , VLT YEL : 11.42
(Ambient temperature 68 °F) WHT VLT : 64.85 , YEL PNK : 10.60
Safety device Internal type
Operating temperature Open °F 248 ± 9
Close °F 171 ± 27
Run capacitor VAC, µF 440 V, 4 µF × 2
Heat exchange
Coil Aluminum plate fin / Copper tube
Rows ..... Fins per inch 2 ... 12.7
Face area ft.
2
(m
2
) 11.63 (1.08)
+ 2.0
+ 0.5
DATA SUBJECT TO CHANGE WITHOUT NOTICE