Chapter 3 Basic Setting and Operation
Examples: Type and contents of alert mail
When the projector has an abnormality, the following alert messages are sent to the regis-
tered E-mail address according to your selected condition. Administrator or user can take
an efficient action quickly by receiving this message. This is very useful to maintain and
service the projector.
The following are examples of received messages.
When internal PJ temperature is too high:
The network unit let users know the information which thermal sensor [A], [B] or [C]
inside the projector detected the abnormal temperature risen and so the projector was
turned off. Please refer to item "Power control and status check" (+ p.46) for the location
of the sensors and each temperature . Also see the owner's manual of the projector for
further details.
TITLE: Message from projector
10-03-2005 00:59
Projector Model Name:
model name
TCP/IP: 192.168.1.201 Projector Name: Proj05
It sends you following message.
* The Projector lamp is turned off, because internal Projector temperature is too high.
Wait for the completion of the cooling process and make sure the projector has been
turned into Standby. Then turn the projector on again.
If the Indicator continues flashing, check the air filter for dust accumulation.
[A] 81.5 degrees fahrenheit [B] 134 degrees fahrenheit [C] 95.6 degrees fahrenheit
Temperature of Sensor B is too high.
When internal PJ power circuit is failed:
TITLE: Message from projector
10-03-2005 00:59
Projector Model Name:
model name
TCP/IP: 192.168.1.201 Projector Name: Proj05
It sends you following message.
*The Projector lamp is turned off, because Projector power circuit is failed.
Unplug the Projector from AC outlet and ask servicing to qualified service personnel.
AV, -5V OK
AV, S5V OK
PJNET, S5V OK
ANALOG, 6V NG
.... .... ....
The projector lamp was turned off, because the projector power circuit failed.
Unplug the projector from AC outlet and ask servicing to a qualified service personnel with
the error information.
Error information