Sanyo DSR - 300 User Manual Page 102

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 101
MENU-SPECIFIC SETTINGS2
English 101
(when optional interface board is installed)
The unit’s hard disk is separated into three independent recording areas. Furthermore, five different recording modes can be
used for these three areas.
The memory capacity for each area is allocated as a percentage. (Setting units: 1%)
(1) Total capacity display
This section displays the total capacity of the hard disk.
(2) Area-specific capacity display
This section displays the capacity set by the unit for each
recording area as a percentage of the total capacity.
z Setting and modification of recording area capacities
cannot be carried out from a PC.
(3) Recording area reset
When the overwrite setting is “OFF”, recording will be
automatically stopped when the corresponding recording
area has been filled with image data. In such a case,
[AREA FULL RESET] can be clicked to clear all recorded
data and to restart recording from the beginning of each
area.
The ability to perform a reset will not be required in the
following cases, and for this reason, [AREA FULL RESET]
is not displayed.
z When the overwrite setting is “ON”.
4. RECORDING AREA SET
Recording area Recording mode Recording method
Normal
recording area
Normal
recording
Manual
Recording is performed in response to manual operation of the operation panel’s
button.
Timer recording Automatic
Recording is performed automatically over the time range set using “7. TIMER SET” from
the MAIN MENU.
Alarm recording
area
Alarm recording Automatic
Recording is performed automatically upon occurrence of an alarm set using “9. ALARM
REC MODE SET” from the MAIN MENU.
Pre-alarm
recording
Automatic
Automatic recording of images before an alarm is performed automatically in
accordance with “PRE-ALARM RECORDING” from the MAIN MENU’s “9. ALARM REC
MODE SET”. This is used as a complementary function for alarm recording.
Archive area Copy Manual
The required images are copied from another recording area and stored in response to
manual operation of the operation panel’s button.
(2)
(3)
(1)
e00_l8had_us_7.book Page 101 Wednesday, March 10, 2004 2:47 PM
Page view 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 135 136

Comments to this Manuals