Sanyo DE User Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 50
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
91
SUPER ABSORPTION
90
ENVIRONMENTALLY FRIENDLY TECHNOLOGY
100mm thick insulation for hot surface
75mm thick insulation for hot surface
Don't insulate the motor,
refrigerant pump and sight glass.
Don't insulate sight glass.
Evaporator cover and chamber cover are
removable in construction
*2 Chamber cover
*2 Chamber cover
50mm thick insulation
for hot surface
50mm thick insulation for hot surface
30mm thick insulation for cold surface
30mm thick insulation for cold surface
Model 100mm 75mm 30mm 50mm 30mm
DE-11 5.8 2.2 2.9 4.0 0.4
DE-12 6.2 2.2 3.0 4.0 0.4
DE-13 7.8 3.2 4.2 5.5 0.4
DE-14 8.0 3.2 4.3 5.5 0.4
DE-21 10.1 3.8 4.9 6.1 0.5
DE-22 10.4 3.8 5.0 6.1 0.5
DE-23 11.8 4.8 5.5 7.6 0.5
DE-24 12.5 4.8 5.6 7.6 0.5
DE-31 14.5 5.5 6.2 8.5 0.7
DE-32 15.2 5.5 6.4 8.5 0.7
DE-41 17.5 5.7 6.8 9.9 0.7
DE-42 18.1 5.7 7.0 9.9 0.7
DE-51 19.6 5.4 7.6 13.8 1.1
DE-52 20.7 5.9 7.9 15.0 1.1
DE-53 21.7 6.2 8.2 16.1 1.1
DE-61 25.4 7.2 9.7 17.5 1.2
DE-62 27.2 7.7 10.1 18.7 1.2
DE-63 28.9 8.2 10.5 20.0 1.2
DE-71 35.4 10.4 12.1 10.9 1.4
DE-72 37.4 10.7 12.4 11.4 1.4
DE-73 39.4 11.0 12.7 11.8 1.4
DE-81 42.5 11.0 13.0 13.1 1.5
DE-82 44.0 11.3 13.5 13.6 1.5
Hot surface
insulation(m
2
)
Cold surface
insulation(m
2
)
Insulation (DE)
Figure 63. Insulation of DE
Evaporator cover
Don't insulate the motor,
refrigerant pump and sight glass.
75mm thick insulation for hot surface
50mm thick insulation for hot surface
Evaporator cover and chamber cover are
removable in construction
30mm thick insulation for cold surface
30mm thick insulation for cold surface
Model 75mm 30mm 50mm 30mm
NE-11 5.2 3.5 4.0 0.4
NE-12 5.2 3.6 4.0 0.4
NE-13 7.3 4.8 5.5 0.4
NE-14 7.3 4.9 5.5 0.4
NE-21 8.3 5.7 6.1 0.5
NE-22 8.3 5.8 6.1 0.5
NE-23 10.5 6.3 7.6 0.5
NE-24 10.5 6.4 7.6 0.5
NE-31 11.6 7.1 8.5 0.7
NE-32 11.6 7.3 8.5 0.7
NE-41 13.0 7.7 9.9 0.7
NE-42 13.0 7.9 9.9 0.7
NE-51 13.8 8.9 13.8 1.1
NE-52 15.4 9.2 15.0 1.1
NE-53 17.0 9.5 16.1 1.1
NE-61 18.4 11.0 17.5 1.2
NE-62 20.2 11.4 18.7 1.2
NE-63 22.0 11.8 20.0 1.2
NE-71 20.9 13.7 10.9 1.4
NE-72 22.6 14.0 11.4 1.4
NE-73 24.6 14.3 11.8 1.4
NE-81 24.4 14.6 13.1 1.5
NE-82 26.4 15.1 13.6 1.5
Hot surface
insulation(m
2
)
Cold surface
insulation(m
2
)
Figure 64. Insulation of NE
Insulation (NE)
Table 16. Insulation data
Table 17. Insulation data
Notice :
1) Material : Glass wool or rock wool (non-combustible type)
2) The total area includes the area of pipes in the chiller/heaters.
3) The machine is coated with rust preventive paint before shipment,
but is not provided with finish paint.
Notice :
1) Material : Glass wool or rock wool (non-combustible type)
2) The total area includes the area of pipes in the chiller.
3) The machine is coated with rust preventive paint before shipment,
but is not provided with finish paint.