4
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor unit KGS1411
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Control PCB
Part No. POW-KGS14A, B
Controls Microprocessor
Control circuit fuse 115V
Flap Motor
Type Stepping motor
Model MP24GA1
Rating DC12V
Coil resistance (ambient temp. 77°F (25°C)) WHT – BLU (respectively 4 wires): 380 ± 7%
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch inch (mm) 1/16 (1.4)
Face area ft
2
(m
2
) 1.40 (0.130)
Fan & Fan Motor
Type Cross-flow
Q’ty … Dia. and length inch (mm) 1 … ø 95 / L617 (ø 3-3/4 / L24-9/32)
Fan motor model … Q’ty KFV4-21HIP … 1P
Nominal output W 15
Coil resistance (ambient temp. 68°F (20°C)) BLU BRN: 104.9
BLU PNK: 128.0
Safety devices Type X23
Operating temp. Open °F (°C) 259 (126) ±4 (±2)
Close
Run capacitor µF 3.5
VAC 180
Remote Control Unit RCS-IRS2U