8-6. Automatic Operation
(1) Normal
Set temperature can be shifted ± 4°F (2°C), in 2°F (1°C) steps.
If operation commences again within 2 hours of the previous operation, the previous setting is applied.
(2) Changing fan speed “Automatic”
Fan speed is automatically selected by the temperature difference between the room temperature (T
R
) and set
temperature (T
S
).
During Heating Operation
During Cooling Operation
Room temperature at start of operation Temperature set automatically Operation mode
T
R
°F (°C) °F (°C)
88 (30) T
R
82 (27)
84 (24) T
R
< 88 (30) 80 (26) Cooling
80 (26) T
R
< 84 (28) 78 (25)
72 (22) T
R
< 80 (26) 76 (24) Dry
T
R
< 72 (22) 76 (24) Heating
Room temperature (T
R
) and set temperature (T
S
) Fan speed
T
R
T
S
+ 4°F (2°C) H / High
T
S
+ 4°F (2°C) > T
R
T
S
+ 2°F (1°C) M / Medium
T
S
+ 2°F (1°C) T
R
T
S
L / Low
T
S
> T
R
(Thermo. OFF) L / Low
Room temperature (T
R
) and set temperature (T
S
) Fan speed
T
R
T
S
H / High
T
S
< T
R
< T
S
+ 2°F (1°C) M / Medium
T
S
+ 2°F (1°C) T
R
(Thermo. OFF) LL / Very Low