48
(4) How to detach combination valve and gas conduit
Remove the screw (1) for the attachment plate of the combination valve in back of the main unit.
Detach the 2 connectors (CN11 for proportional valve and CN08 for solenoid valve).
Remove the screws (2) attaching the gas conduit in front of the combustion chamber, and take off the
combination valve with gas conduit.
(5) How to detach combination valve
Remove the attachment screws, and dismantle as shown below.